![Necta KIKKO ES6 Installation, Use And Maintenance Manual Download Page 20](http://html1.mh-extra.com/html/necta/kikko-es6/kikko-es6_installation-use-and-maintenance-manual_3820810020.webp)
© by NECTA VENDING SOLUTIONS SpA
16
02-2004 184 02
STATISTICS
Data on the machine operations is stored in both general
counters and relative counters, which can be reset without
losing total data.
Connect an RS232 serial printer having a Baud rate of
9600, 8 data bit, no parity, 1 stop bit to the serial port located
on the push button board to print all of the statistics, and
namely:
Total
1 - counter by single selection;
2 - counter by time bands;
3 - discount counter;
4 - failure counter;
5 - coin mechanism data.
Relative
1 - counter by single selection;
2 - counter by time bands;
3 - discount counter;
4 - failure counter;
5 - coin mechanism data.
The printout will also contain the machine code, the date
and the software version.
To connect the printer, do as follows:
- press the confirm print button “ ”, displaying the mes-
sage “Confirm?”;
- connect the printer before confirming;
- press the confirm button “ ” to start printing.
DISPLAY
When pressing the confirm button “ ” the data described
in the paragraph “Printing the statistics” is sequentially
displayed.
DELETE STATISTICS
Statistics can be reset for relative counters globally (all
types of data) or selectively for:
- selections
- failures
- coin mechanism data
Press the confirm button “ ”, and the message “Confirm?”
starts blinking.
Press the confirm button “ ”, the message “Working” is
displayed for a few seconds and all statistics are reset.
SELECTION PRICES
This function is used for changing the sales price for each
selection or for all selections simultaneously for each time
band that may be set.
CHANGE TUBES CONTROL
By accessing the “Tube control” function the change tubes
can be filled or released manually.
Confirm refilling, and the display will indicate
“Credit: ——” which is the value of money available in
change the tubes; insert the desired coin into the selector
and the display will indicate the value of money available in
the change tubes.
When confirming releasing, it will be possible to decide
which tube to release. Each time the confirm button “ ” is
pressed, a coin is ejected from the active tube.
DISPLAYING THE TEMPERATURE
With this function it is possible to read the boiler tempera-
ture directly in °C.
TEST DISPENSING
For complete or a partial dispensing tests each key is
assigned a selection (see the dose selection table).
N.B. For tea-based selections, only the additions are
dispensed with the partial dispensing of water.
GSM PRE-ALARMS
The control software can send, via GSM modem, a signal
indicating an “ending product” signal, when there is only a
certain (programmable) number of pieces or grams of
powder of a given product left. With this function the
counters that control the pre-alarms are reset.
EVADTS TRANSFER
When activating this function, the machine awaits the
connection with a device to acquire the EVADTS statistics.
Summary of Contents for KIKKO ES6
Page 2: ......
Page 4: ......
Page 65: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 66: ...Sx372 01...
Page 67: ...Kikko instant...
Page 68: ...Sx374 02...
Page 69: ...Kikko espresso...
Page 70: ...Sx373 01...
Page 71: ...Kikko...
Page 72: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 73: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 74: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 76: ......