![NEC XEN IPK DIGITAL TELEPHONE Programming Manual Download Page 544](http://html.mh-extra.com/html/nec/xen-ipk-digital-telephone/xen-ipk-digital-telephone_programming-manual_248366544.webp)
December 2004
NEC Business Solutions Ltd
524 – Chapter 1
DRAFT 3
Section 5, Function Timer Chart
Doc. No.: 81
94 - Release 2.0
December 2004
Automated
Attendant Transfer
Delayed Ringing
Time Selection
1-4-02
Specify the time for a No Answer
at the transferred station before
the Automated Attendant rings a
predetermined station.
10 sec.
No Limit
No Limit
Automated
Attendant No
Answer Disconnect
Time Selection
1-4-03
Determine how long the
Automated Attendant rings a
station before dropping the call.
1 min.
2 min.
4 min.
Automated
Attendant Answer
Delay Time
Assignment
1-4-13
Assign the number of seconds
before the Automated Attendant
answers an incoming CO/PBX call
when there is no answer.
0 sec.
4 sec.
99 sec.
Automated
Attendant 1st to 2nd
Delay
Announcement
Interval Time
Selection
1-4-19
Specify the interval time between
the Automated Attendant Delay
Announcement messages
0 min.
4 min.
20 min.
Automated
Attendant Delay
Announcement
Disconnect Time
Selection
1-4-20
Establishes how long the
Automated Attendant rings the
stations before disconnecting the
caller. Only applies when the
Automated Attendant is set to the
Delay Announcement Mode.
0 sec.
30 sec.
20 min.
SMDR Valid Call
Timer Assignment
1-5-25
Minimum duration of an outside
call before the system provides an
SMDR report (Set from 0~99
seconds in 10-second
increments).
0 sec.
40 sec.
990 sec.
Doorphone Display
Time Selection
1-7-01
Define how long a door phone call
signals a station before it times
out.
10 sec.
10 sec.
90 sec.
External Paging
Timeout Selection
1-7-06
The time before an external
paging is automatically
disconnected.
30 sec.
5 min.
No Limit
External Speaker
Chime Start Time
Selection
1-7-09
Assign the delay after an external
paging code is dialled and before
the paging alert tone is provided.
Only used when paging alert tone
(4 tones) is assigned in Memory
Block 1-7-08 (External Speaker
Chime Selection).
0 ms.
700 ms.
1500 ms.
Table 1-3:
Function Timer Chart (Continued)
Timer
Memory
Block
Definition
Timing Value
Minimum
Default
Maximum