468 – Chapter 1
DRAFT 3
Timer Class Assignment for Telephone Mode Selection, 4-64
December 2004
NEC Business Solutions Ltd
Doc.
No.: 8194 -
Release 2.0
Dece
mber 2004
Submode
4
System Mode
—
Data No.
64
PC Programming
+ BTT
Timer Class Assignment for
Telephone Mode Selection
General Description
This Memory Block assigns class of flexible timer to Extenstions. Applicable to IPK R2000.
Display
Programming Procedures
1
Go off-line.
2
Press LK4 +
GA
to access the Memory Block.
3
Use the following to enter data:
J
to move the cursor left.
L
to move the cursor right.
K
~
I
to enter numeric data.
Setting Data (Allow):
1 (Class 1) to 4 (Class 4)
– OR –
Press
R
to go to the next TEL port number.
Default
Class 1
4
Press
N
to write the data and display Memory Block , 4-01.
5
Program Memory Block, 4-01 or press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-1-03
Hold Recall Timer Selection (Non-Exclusive Hold)
Start Timer Selection
CO/PBX Incoming Ringing Alarm Time Selection
1-1-07
Tie/DID Line Delay Ringing Timer Selection
1-1-12
Station Transfer/Camp-On Recall Timer Selection
1-1-37
Trunk Queuing Timeout Selection
1-1-63
Hold Recall Time Selection (Exclusive)
1-1-81
ISDN Dial Interval Timer
1-2-00
Internal Paging Timeout Selection
0 1 / 7 1 : T M R
C L S = 1 5
T I M E
D I S P L A Y
Data
No.
Tel Port No.
(01~CO)
Setting
Data