1-4-03, Automated Attendant No Answer Disconnect Time Selection
DRAFT 3
Chapter 1 – 171
Doc. No.: 8194
- Release 2.0
December 200
4
3
Use the dial pad to enter the time required.
Note
:
J
to move cursor left.
L
to move cursor right.
Setting Data (Allow): 001 to 255 sec
Default value: 120 sec
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Refer to
Chapter 2, Guide to Feature Programming.
4-71
Time Class Assignment for Telephone Mode (R2000 and above)
N
1. If the called party does not answer in the predetermined time, the call is dropped.
2. If Busy Tone Detector is enabled in Memory Block, 3-39, then disconnection of an abandoned call during an
Automated Attendant message will be performed by the Trunk Card.
3. If Busy Tone Detector is not enabled, then Abandoned Call will continue to ring in the system for the duration of the
time set in Memory Block , 1-4-03.
Programming Procedures