![NEC XEN IPK DIGITAL TELEPHONE Programming Manual Download Page 126](http://html.mh-extra.com/html/nec/xen-ipk-digital-telephone/xen-ipk-digital-telephone_programming-manual_248366126.webp)
106 – Chapter 1
DRAFT 3
Code Restriction Class Allow/Deny Selection, 1-1-65
December 2004
NEC Business Solutions Ltd
Doc.
No.: 8194 -
Release 2.0
Dece
mber 2004
1-1-65
System Mode
1
Submode
1
Data No.
65
PC Programming
+ AC
Code Restriction Class Allow/
Deny Selection
General Description
Use this Memory Block to assign Code Restriction Classes 01~14 as Allow or Deny. This
assignment is used when there is no match or there is an overlap (duplicate numbers in tables
with opposite assignments) of numbers in the 8-Digit Matching Tables.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates
the default setting.
Allow (YS)
Deny (NO)
LK 5
LK 6
LK 7
LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 +
LK1 +
FE
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change data option.
Default Values
Class 01
Deny (NO)
Class 02~14
Allow (YES)
4
Press
N
to write the data and advance to the next class. Repeat steps 3 and 4 until last class is assigned.
5
Press
N
to write selected data.
6
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Refer to
in this chapter.
N
1. If a match is not found or duplicate match is made with opposite assignments, the system uses this Memory Block.
2. If the interdigit dialling time duration exceeds 10 seconds while a restricted station user is dialling on an outside line,
the system automatically drops the call.
3. If phones are required to dial emergency “only”, then class 01 can be used.
4. Use Memory Block 1-1-70 as the default class assignment for features such as station outgoing lockout In/Out (from
DSS console and password lockout.
6 5 : C L A S S
( 0 1 ) = Y S
T I M E
D I S P L A Y
Data
No.
Class
No.
01~14
Title
Function