Xen IPK
Programming Manual
Section 5, Function Timer Chart
DRAFT 3
Chapter 1 – 523
Doc. No.: 8194
- Release 2.0
December 200
4
Delayed Ringing
Timer Assignment
(ICM)
1-2-26
Specify the time for delayed
ringing on internal calls.
0 sec.
10 sec.
99 sec.
PS Out of Area
Timer Selection*
1-2-30
Assigns Out of Area PS Timer
00 sec.
12 sec.
99 sec.
Bounce Protect
Time Selection
1-3-01
Specify the time before a valid
hookflash is detected from a
Single Line Telephone or Voice
Mail System.
0 ms.
300 ms.
1500 ms.
First Digit PBR
Release Timer
Selection
1-3-03
Specify the time that a receiver is
connected when a DTMF Single
Line Telephone user is dialling.
10 sec.
10 sec.
60 sec.
Hookflash Start
Time Selection
1-3-05
Specify a minimum hookflash
duration for a Single Line
Telephone to receive a second
dial tone.
40 ms.
290 ms.
790 ms.
Hookflash End
Time Selection
1-3-06
Specify a maximum duration from
a Single Line Telephone to receive
a second dial tone (HT =
Hookflash Start Time).
HST + 0 ms.
HST + 700
ms.
HST + 1500
ms.
Voice Mail DTMF
Delay Timer
Selection
1-3-08
Specify the delay time before
DTMF tones are sent to the VMI
port.
0 sec.
1 sec.
8 sec.
Voice Mail
Disconnect Time
Selection
1-3-09
Specify the sending time of a
disconnect signal that is sent to
the connected equipment.
.5 sec.
1.5 sec.
3.5 sec.
Voice Mail DTMF
Duration/Interdigit
Time Selection
1-3-10
Specify the DTMF duration/
interdigit time for voice mail.
60/70 ms.
110/80 ms.
810/190 ms.
Tandem Transfer
Automatic
Disconnect Timer
Selection
1-4-00
Specify a maximum time before
automatic disconnect of a Trunk-
to-Trunk transfer occurs.
30 min.
1 hr.
3 hr.
Tandem Transfer
Automatic
Disconnect Timer
Selection*
1-4-00
Specify a maximum time before
automatic disconnect of a Trunk-
to-Trunk transfer occurs.
000 min.
060 min.
999 min.
Automated
Attendant First Digit
PBR Release Timer
Selection
1-4-01
Specify the PBR connection time
to the Automated Attendant trunk
to receive the DTMF signal from
the calling party before
automatically disconnecting.
5 sec.
20 sec.
60 sec.
Table 1-3:
Function Timer Chart (Continued)
Timer
Memory
Block
Definition
Timing Value
Minimum
Default
Maximum