![NEC XEN IPK DIGITAL TELEPHONE Programming Manual Download Page 534](http://html.mh-extra.com/html/nec/xen-ipk-digital-telephone/xen-ipk-digital-telephone_programming-manual_248366534.webp)
December 2004
NEC Business Solutions Ltd
514 – Chapter 1
DRAFT 3
ROM Version Confirmation, 8-1
Doc. No.: 81
94 - Release 2.0
December 2004
5
Frame number, slot number, interface name, and ROM Version are shown on the display. There are three display patterns.
1) For basic frame (frame 1 or slot C) CPU:
2) For slot C of expansion frame:
3) For another slot type:
6
Press
N
to write the data.
7
Press
P
to go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
Programming Procedures (Continued)
S P 6 0
: M M C = 0 1
1 - 0 C : C P U
= 1 . 0 2
Unit Name
Frame
No.
1~3
Slot No.
C, 1~8
A, B
ROM Version of
CPU
1 —
: O C :
= 0 1
0 9 : N O N
= 0 0
1 — 0 1 : B R T
4
= 0 0
Upper
Slot No.
9~16
ROM
Version
ROM
Version
No. 01~15
Unit Name
Lower
Slot No.
1~8,
(A, B)
Frame
No.
1~3
Unit Name