![NEC XEN IPK DIGITAL TELEPHONE Programming Manual Download Page 379](http://html.mh-extra.com/html/nec/xen-ipk-digital-telephone/xen-ipk-digital-telephone_programming-manual_248366379.webp)
3-21, Tie Line Length of Wink Signal Selection
DRAFT 3
Chapter 1 – 359
Xen IPK
Programming Manual
Doc. No
.: 8194 -
Rele
ase 2.
0
December
2004
System Mode
3
Submode
—
Data No.
21
PC Programming
+ ALM
Tie Line Length of Wink
Signal Selection
General Description
Use this Memory Block to specify the duration of a wink pulse that is sent to another system.
Display
Settings
(Page 1)
LK 1
LK 2
LK 3
LK 4
The shaded area indicates
the default setting.
30 ms.
60 ms.
90 ms.
120 ms.
LK 5
LK 6
LK 7
LK 8
150 ms.
180 ms.
210 ms.
240 ms.
(Page 2)
LK 1
LK 2
LK 3
LK 4
270 ms.
300 ms.
330 ms.
360 ms.
LK 5
LK 6
LK 7
LK 8
390 ms.
420 ms.
450 ms.
480 ms.
Programming Procedures
1
Go off-line.
2
Press LK3 +
N
+
BA
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note:
Use the following to enter data:
S
to go to the next page
T
to go to the previous page
R
to go to the next CO/PBX Line No.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
0 1 / 2 1 : W I N K 1 8 0
| 1
T I M E
D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Page
No.
Setting
Data
Wink Pulse Sending
Receiving Side
Incoming Signal Detection
Time
DC Loop Supervision