The examples in this section are only a guide to the configuration required on the SV9100 to install AspireNet
Operation.
5.1
AspireNet - ISDN BRI
AspireNet Basic Rate ISDN is supported on all BRI PCB’s (2, 4 or 8 BRIU). Each circuit of the BRIU PCB
can be set independently to Trunk / S0 / AspireNet mode.
Each circuit set as AspireNet mode will require 2 of the AspireNet ports on the system, there are a total of
256 AspireNet ports available.
The example below shows two SV9100 systems, each has a BRIU card installed with one circuit set to
Mode 4 for AspireNet . The two BRIU circuits are cross connected via a 2-pair twisted cable.
SV9100 A has extension numbers in the range 200-299, SV9100 B has 300-399.
More than one circuit required.
If more BRI circuits were added then Program 10-03-xx would copied for each new circuit.
Master/Slave setting
The choice of Master/Slave of each circuit is not important in the example above as there is no ISDN Net-
work connection to either of the systems.
If System A had an ISDN Network connection (BRI trunk or PRI trunk) then System A would be the Master
for AspireNet circuits.
If both system A and System B have an ISDN Network connection then the setting of Master/Slave is not
important.
When the AspireNet BRI circuit is connected to external equipment then ensure that the equipment is set
to Master (Clock generator) or Slave (Clock receiver) accordingly.
SV9100 A
SV9100 B
Program 10-03 BRI PCB Setup
10-03-01 = Mode 4
10-03-03 = P-P
10-03-10 = Master
10-03-11 = 1
Program 10-03 BRI PCB Setup
10-03-01 = Mode 4
10-03-03 = P-P
10-03-10 = Slave
10-03-11 = 1
Program 11-01-01 System Numbering
Dial 2x = 3 digit, Type 2 (Intercom)
Dial 3x = 3 digit, Type 8 (Networking),
ID=1
Program 11-01-01 System Numbering
Dial 2x = 3 digit, Type 8 (Networking),
ID=1
Dial 3x = 3 digit, Type 2 (Intercom)
SV9100 A
SV9100 B
2-pair twisted cable
Summary of Contents for Univerge SV9100
Page 1: ...Networking Manual A50 035910 004 AU Issue 2 0...
Page 20: ...xviii Table of Contents Issue 2 0...
Page 26: ...xxiv List of Figures Issue 2 0...
Page 33: ...Book 1 SV9100 K CCIS...
Page 49: ...Issue 2 0 1 16 General Information US Only Figure 1 15 Circuit Identification Codes CIC...
Page 53: ...Issue 2 0 1 20 General Information US Only...
Page 61: ...Issue 2 0 2 8 Hardware Installation US Only...
Page 195: ...Issue 2 0 4 116 Features and Specifications...
Page 242: ...Book 2 SV9100 IP Networking...
Page 256: ...Issue 2 0 2 12 IP Networking...
Page 312: ...Issue 2 0 4 48 Programming...
Page 376: ...Issue 2 0 6 30 SIP Trunking...
Page 391: ...Issue 2 0 7 14 H 323 Trunking...
Page 467: ...Issue 2 0 8 76 IP Multiline Station SIP...
Page 551: ...Issue 2 0 10 64 SV9100 NetLink Conditions None Feature Cross Reference None...
Page 567: ...Issue 2 0 10 80 SV9100 NetLink Conditions None Feature Cross Reference None...
Page 579: ...Issue 2 0 11 6 NAPT...
Page 580: ...Issue 2 0 SV9100 Networking Manual 11 7...
Page 581: ...Issue 2 0 11 8 NAPT...
Page 582: ...Issue 2 0 SV9100 Networking Manual 11 9...
Page 583: ...Issue 2 0 11 10 NAPT...
Page 584: ...Issue 2 0 SV9100 Networking Manual 11 11...
Page 595: ...Issue 2 0 12 4 All DSP Busy Indication...
Page 671: ...Issue 2 0 13 76 AspireNet Conditions None Feature Cross Reference None...
Page 685: ...Issue 2 0 13 90 AspireNet Department Calling Flexible System Numbering Intercom...
Page 707: ...Issue 2 0 13 112 AspireNet Default Trunk Port Number Name 1 Line 001 2 Line 002 400 Line 400...
Page 713: ...Issue 2 0 13 118 AspireNet Department Calling...
Page 765: ...Issue 2 0 13 170 AspireNet...