Setting Up the System
Assembly
This section describes how to assemble your rack-mount server unit into a standard IAE
19 inch rack cabinet.
CAUTION
Ensure that the location of the rack-mount server unit does not
create an unstable condition when installed in the rack cabinet.
1.
Select an appropriate location in your rack cabinet for the rack-mount server unit. To improve
rack stability, mount heavier items towards the bottom of the rack cabinet.
Note:
When planning your system configuration for the rack
cabinet you should consider the length of the cables that
interconnect system components.
2.
Locate the two support brackets (D). Using four self tapping screws (E) supplied with the rack
cabinet for each support bracket, attach the two support brackets to the vertical mounting rails
(A and B) of the rack cabinet.
3.
Install the four caged nuts (C) that secure the front of the rack-mount server unit to the rack
cabinet. Position the caged nuts to align with the screw holes in the front bezel of the rack-
mount server unit.
Note:
The caged nuts are secured into the vertical mounting
rails of the rack cabinet by inserting one side of the nut into the slot
and squeeze while pressing the opposite side until it snaps into
place.