Cell Interconnect Cabling
4-9
y
The B connector has a blue band.
Use the following procedure to connect the interconnect cables:
1. Review the table showing the cell interconnect cabling for your configuration.
Follow the order presented in this table when cabling the cells.
2. To connect the cables to the cells, fully seat the cable on the socket, and then
tighten the retaining screws with your fingers.
3. Route and secure each cable in the cable manager, located on the right side of the
cabinet when facing the back, before proceeding to the next cable.
4.3.1.
System with Two Cells
Follow the order presented in
Table 4-1
for correct placement of interconnect cables.
Table 4-1 Two-Cell Interconnect Cabling
Line #
Connect From (Blue)
Connect To (Amber)
1
Cell 0 Port 0
Cell 1 Port 0
2
Cell 0 Port 1
Cell 1 Port 1