1. Installing Internal Optional Devices
Express5800/R120d-2E User’s Guide
84
Chapter 2 Preparations
(1) When using the optional controller (N8103-149/150/151/152)
For details, refer to the manual that comes with optional RAID Controller (N8103-149/150/151/152).
Important You must avoid static electricity to work with the procedure below. For
details, refer to
Chapter 2 (1.2 Anti-static Measures)
.
Note
•
When installing an optional RAID Controller, start the BIOS Setup utility, select
PCI Configuration
from the
Advanced
menu, and then make sure that the
parameter of
PCI Slot
xx
ROM
(
xx
is PCI slot number) is set to
Enabled
.
•
When connecting a RAID Controller, set the boot priority to 8th or higher in the
Boot menu of the BIOS Setup utility. If the setting is 9th or lower, the
configuration menu for RAID Controllers cannot be launched.
[Installing optional PCI card in slot PCI #1B, 2B, 3B, 1C, or 2C]
1. Refer
to
Chapter 2 (1.3 Overview of Installation and Removal)
for preparations..
2.
Remove the two screws securing the rise
card B. Hold the both ends of the riser
card B and lift it straight to remove.
Note
Be careful not to contact with other parts.
3.
Confirm the installation position with the reference to the table in (
1.13.2 Supported cards and available
slots
).
4.
Remove the blank cover from the rise card
(common to PCI slots #1B to 3B, 1C, and
2C) .
Note
Keep the blank cover for future use.
①
②
Screws