Smooth Operator Configuration Note (77175)
NEC Neax 2400 w/ Direct Serial Link
C o n f i d e n t i a l
P a g e 4
The above information is provided by Octel Communications Corporation as a guide.
See disclaimer on page 1
O c t e l C o m m u n i c a t i o n s
To allow blind transfer to the attendant(s) console, enter system programming.
Assignment of System Data
SYS :
1
SYS:
System Data Items
INDEX : 5
DATA: XX
1-System Data 1
2-System Data 2
3-System Data 3
INDEX:
System Data Index
System
Index
1
0-255
2
0-15
3
0-31
DATA:
System Data (Hexadecimal)
SYS:
Allow blind transfer to the attendant(s) console is a system-wide
parameter,
type
1
in this field, then press
ENTER
.
INDEX:
Enter
17
for allow blind transfer to the attendant(s) console.
DATA:
Minimum value is 08 to enable bit 4. Consult the System
Administrator for proper value. For 4200 or 5200 Rel I series
software an application disk must be loaded.
5.2 CONFIGURING THE SINGLE LINE PORTS
The following screens are taken from a NEAX MAT terminal.
* * *
2400 MAINTENANCE COMMAND MENU
* * *
1 SYSTEM
CONTROL
2 SYSTEM
BACKUP
3
MAKE BUSY CONTROL
4 TRAFFIC
DATA
5 TEST
6 STATION
DATA
7 TRUNK
DATA
8 NUMBERING
PLAN
9
SERVICE FEATURE DATA (1)
10
SERVICE FEATURE DATA (2)
11
SIGNAL TRANSLATION DATA
12 RESTRICTION
DATA
13 INSTALLATION
14 LIST
UP
ENTER MENU ITEM NO [
6
]