DATA
: Setting DATA to
02
sets bit 1 to tell the Switch that the MCI
Service is for calls via Attendant Console. This value should not
be changed without consulting the System Administrator.
5.5 DATA LINK CONFIGURATION FOR THE MCI
Set up the MCI I/) port (P/N PAI002) to the same baud, parity, data bit and
stop bit settings as the NEC.CFG file in the Smooth Operator system. If
the MCI data link is configured for 2 stop bits it should be reconfigured for
1 stop bit. 2 stop bits will cause inconsistent operation of the MCI link.
Note: After making any changes to the Data Link on the NEAX you
must Reboot the switch for the changes to take effect. If you make
changes to the Integration Configuration program of the Smooth
Operator system, you must exit the Smooth Operator system and
relaunch it by rebooting the PC..
The normal settings for the MCI data link are 1200 baud, 8 data bits, 1 stop
bit, and no parity bit. Below are the jumper settings that are needed to
achieve this.
Switch
Settings
Function
SW01/ 1 2 3
SW11 on off on
1200
BPS
4
off
Parity bit invalid
5
off
Even
parity
6
off
8
bits
7
on
1 stop bit
8
on
Send side FIFO is 1 byte.
8
off
For version 5200 J4.38 and above set switch
8
off.
Switch
Settings
Function
SW02/
1
on
When PB lead is - terminal is busy
SW12
2
on
DTR signal is always on
3
on
DSR signal is not provided
4
on
CD is not provided
5
on
CS is not provided
6
on
CI is not provided
7
on
PB signal is not provided
8
off
Not
used
Switches 01 and 02 are configured when you are using port 0 on the I/O
card, 11 and 12 are configured when you are using port 1.
5.6 PROGRAMMING THE STATION SETS