background image

Smooth Operator Configuration Note (77175)

 

NEC Neax 2400 w/ Direct Serial Link

C o n f i d e n t i a l

P a g e   6

 

The above information is provided by Octel Communications Corporation as a guide. 

  See disclaimer on page 1 

O c t e l   C o m m u n i c a t i o n s  

When programming a port, you may need to change the Tenant Number.  
You will need to select and enter a proper Station Number and Line 
Equipment Assignment.  

Telephone Class

 must be set to 

3

.  A Route 

Restriction Class and Service Feature Class must be selected.  There are no 
known conflicts with the options in either Route Restriction Class or 
Service Feature Class at this time. 

 
Assignment of Station Data 
  

  

TN: 

Tenant 

Number 

TN: 

STN:   

100

 STN: 

Station 

Number 

LENS: 

   

000000

 

 

LENS:  Line Equipment Number (6 Digits) 

TEC:  

3

      RSC:   0    SFC:   0 

TEC:  Telephone Class (1-31) 

 

 

 

 

  1-DP 

(10PPS) 

22-EMM 

 

 

 

 

  2-PB 

 

 

 

 

  3-DP/PB 

 

 

 

 

  11-VMM/VMZ 

 

 

 

 

  12-Dterm 

 

 

 

 

    13-Data Terminal Via Dterm V 

 

 

 

 

  14-Hot 

Line 

 

 

 

 

  15-Cas 

Line 

RSC: Route Restriction Class (0-15) 

    16-Data Terminal via Data Module 

        For assignment of RSC, ARSC command   18-Virtual Line Appearance 
SFC:  Service Feature Class (0-15) 

    19-TMM 

         For assignment of SFC, ASFC command    20-PSM 
 

 

When you are done editing the final field on this screen, press the 

ENTER

 key 

to confirm the single line station programming.  When assigning the first 
station data command for a Line Package, the message "

PKG CHECK

" will 

be displayed on the screen.  At this point, check that the right circuit card is in 
the slot on the switch and then press the 

ENTER

 key.  All assignments to the 

same Line Package, after the initial one, will prompt you with a "

WRT?

message after entering the station data.  Type "

Y

" then press the 

ENTER

 key 

to confirm your information.  The cursor will then move to the first field, 
allowing you to configure the next single line port.  Repeat this step for each 
single line port. 

When you have configured all your single line ports, press the

 \

 

(BACKSLASH) key to return to the Station Menu. 

Summary of Contents for NEAX 2400

Page 1: ...s NEC Neax 2400 MCI Link on NEC 1 0 METHOD OF INTEGRATION RS 232 Direct Serial Integration Smooth Operator communicates with the NEAX 2400 using Feature 2 of the Message Center Interface MCI Call for...

Page 2: ...port OR one RJ 14 Jack for every two Brooktrout TR 114 fax ports along with 4 conductor modular telephone cords 3 1 SWITCH SOFTWARE REQUIREMENTS NEAX 2400 SIM or IMG 5200 NEAX 2400 MMG or UMG 4200 or...

Page 3: ...at the MCI is not a MAT terminal Note In the following examples 100 will represent the UCD pilot number for Voice Mail Single Line extensions to the Smooth Operator will be 100 101 102 and 103 5 1 NEA...

Page 4: ...S Allow blind transfer to the attendant s console is a system wide parameter type 1 in this field then press ENTER INDEX Enter 17 for allow blind transfer to the attendant s console DATA Minimum value...

Page 5: ...D CM01 14 RSHU Remove Station Hunting UCD CM01 15 AUOG Assignment of UCD Overflow Group CM01 ENTER MENU ITEM NO 1 Select ASSIGNMENT OF STATION DATA option by typing 1 then press the ENTER key Enter Th...

Page 6: ...13 Data Terminal Via Dterm V 14 Hot Line 15 Cas Line RSC Route Restriction Class 0 15 16 Data Terminal via Data Module For assignment of RSC ARSC command 18 Virtual Line Appearance SFC Service Feature...

Page 7: ...ent of UCD Overflow Group CM01 ENTER MENU ITEM NO 13 From the Station Data Menu type 13 for Assignment of Station Hunting UCD Press the ENTER key The Tenant Number that was used when configuring the s...

Page 8: ...ingle line port 102 After entering the extension press ENTER The screen will update in the same manner prompting you for the fourth member of the UCD group After entering the data for the final UCD me...

Page 9: ...eps represent the minimum requirements necessary for the MCI integration to work correctly The data field entered may be different for each installation and should never be changed without first consu...

Page 10: ...System Data 3 INDEX System Data Index System Index 1 0 255 2 0 15 3 0 31 DATA System Data Hexadecimal SYS MCI data link programming is a system wide parameter type 1 in this field then press ENTER IN...

Page 11: ...nput for index 34 Bit System Data Contents 0 0 1 Out In services for SMDS and MCI link 1 2 0 No parity 2 No parity 4 Odd parity 6 Even parity 3 4 0 Unused 8 1 Stop bit 10 1 5 stop bits 18 2 Stop bits...

Page 12: ...sis Type 2 in this field then press ENTER TN You need to use the same tenant value you used when creating the Single Line ports and UCD group INDEX Index 6 includes field that allow you to associate t...

Page 13: ...AX you must Reboot the switch for the changes to take effect If you make changes to the Integration Configuration program of the Smooth Operator system you must exit the Smooth Operator system and rel...

Page 14: ...ion key for busy forward at this point you will get a second dial tone 3 Dial the forwarding target number This is the first member extension of the UCD group Cancel Forward Busy 1 Lift handset of pho...

Page 15: ...ait for First Digit 1 Location of Inband Signaling Code 1 Millisecs to Wait for Next Digit 100 Code for Go to Voice Mail F Start at End of String for Go to Voice Mail Enabled Location of Mailbox Numbe...

Page 16: ...essage waiting lights may not work Try setting the protocol of the Serial link to odd parity seven data bits and two stop bit 1200 7 O 2 7 0 CONSIDERATIONS ALTERNATIVES The following items should be c...

Page 17: ...x 2400 w Direct Serial LinkC o n f i d e n t i a l P a g e 1 7 The above information is provided by Octel Communications Corporation as a guide See disclaimer on page 1 O c t e l C o m m u n i c a t i...

Reviews: