Smooth Operator Configuration Note (77175)

 

NEC Neax 2400 w/ Direct Serial Link

C o n f i d e n t i a l

P a g e   3

 

The above information is provided by Octel Communications Corporation as a guide. 

  See disclaimer on page 1 

O c t e l   C o m m u n i c a t i o n s  

  

Intercom 

Paging

 

[

9

 

 

 

 

Record Telephone Conversation 

  

 

4.1 DISCONNECT 

TYPE 

Disconnect is achieved by either Drop in Loop or Fast busy. For proper 
external disconnect supervision, Ground start or Supervised Loop start CO 
lines are recommended.   

(see Note 7.1) 

 

5.0  CONFIGURING THE NEC NEAX 2400 

Before you begin programming, it is recommended that a hard copy of the 
customer database be obtained to verify existing programming. 

When configuring the MCI link, the switch system administrator should be 
contacted to avoid possible programming conflicts.  Remember to instruct 
the SWITCH that the MCI is not a MAT terminal. 

Note:  In the following examples, 100 will represent the UCD pilot number 
for Voice Mail.  Single Line extensions to the Smooth Operator will be 100, 
101, 102 and 103.  

5.1   NEAX 2400 SYSTEM PROGRAMMING 

Refer to the Programming section in the NEC manual for information on 
entering, saving, and exiting database programming. 

To allow multiple call forward to personal greeting, enter system 
programming.  Data will specify the number of hops allowed on calls 
forwarded under Busy/No answer conditions. 

Assignment of System Data 
 

 

 

 

SYS :   

 

 

 

 

SYS: 

System Data Items 

INDEX : 

5

 DATA: 

XX

 

 

    1-System Data 1   

 

 

 

 

 

 

    2-System Data 2 

 

 

 

 

 

    3-System Data 3 

 

 

 

 

 

INDEX: 

System Data Index 

  

  

 

 

 

System 

Index 

   

  

 

 

 

 1 0-255 

   

  

 

 

 

 2 0-15 

   

  

 

 

 

 3 0-31 

  

  

 

DATA: 

System 

Data 

(Hexadecimal)  

 
SYS:

 

Number of hops allowed on calls forwarded is a system-wide  

  parameter, 

type 

in this field, then press 

ENTER

INDEX:

 Enter 

5

 for number of hops allowed on calls forwarded. 

DATA: 

Max value allowed is 05 for 5 hops. Consult the System  

 

 

Administrator for proper value.  

Programming switch system 

parameters 

Summary of Contents for NEAX 2400

Page 1: ...s NEC Neax 2400 MCI Link on NEC 1 0 METHOD OF INTEGRATION RS 232 Direct Serial Integration Smooth Operator communicates with the NEAX 2400 using Feature 2 of the Message Center Interface MCI Call for...

Page 2: ...port OR one RJ 14 Jack for every two Brooktrout TR 114 fax ports along with 4 conductor modular telephone cords 3 1 SWITCH SOFTWARE REQUIREMENTS NEAX 2400 SIM or IMG 5200 NEAX 2400 MMG or UMG 4200 or...

Page 3: ...at the MCI is not a MAT terminal Note In the following examples 100 will represent the UCD pilot number for Voice Mail Single Line extensions to the Smooth Operator will be 100 101 102 and 103 5 1 NEA...

Page 4: ...S Allow blind transfer to the attendant s console is a system wide parameter type 1 in this field then press ENTER INDEX Enter 17 for allow blind transfer to the attendant s console DATA Minimum value...

Page 5: ...D CM01 14 RSHU Remove Station Hunting UCD CM01 15 AUOG Assignment of UCD Overflow Group CM01 ENTER MENU ITEM NO 1 Select ASSIGNMENT OF STATION DATA option by typing 1 then press the ENTER key Enter Th...

Page 6: ...13 Data Terminal Via Dterm V 14 Hot Line 15 Cas Line RSC Route Restriction Class 0 15 16 Data Terminal via Data Module For assignment of RSC ARSC command 18 Virtual Line Appearance SFC Service Feature...

Page 7: ...ent of UCD Overflow Group CM01 ENTER MENU ITEM NO 13 From the Station Data Menu type 13 for Assignment of Station Hunting UCD Press the ENTER key The Tenant Number that was used when configuring the s...

Page 8: ...ingle line port 102 After entering the extension press ENTER The screen will update in the same manner prompting you for the fourth member of the UCD group After entering the data for the final UCD me...

Page 9: ...eps represent the minimum requirements necessary for the MCI integration to work correctly The data field entered may be different for each installation and should never be changed without first consu...

Page 10: ...System Data 3 INDEX System Data Index System Index 1 0 255 2 0 15 3 0 31 DATA System Data Hexadecimal SYS MCI data link programming is a system wide parameter type 1 in this field then press ENTER IN...

Page 11: ...nput for index 34 Bit System Data Contents 0 0 1 Out In services for SMDS and MCI link 1 2 0 No parity 2 No parity 4 Odd parity 6 Even parity 3 4 0 Unused 8 1 Stop bit 10 1 5 stop bits 18 2 Stop bits...

Page 12: ...sis Type 2 in this field then press ENTER TN You need to use the same tenant value you used when creating the Single Line ports and UCD group INDEX Index 6 includes field that allow you to associate t...

Page 13: ...AX you must Reboot the switch for the changes to take effect If you make changes to the Integration Configuration program of the Smooth Operator system you must exit the Smooth Operator system and rel...

Page 14: ...ion key for busy forward at this point you will get a second dial tone 3 Dial the forwarding target number This is the first member extension of the UCD group Cancel Forward Busy 1 Lift handset of pho...

Page 15: ...ait for First Digit 1 Location of Inband Signaling Code 1 Millisecs to Wait for Next Digit 100 Code for Go to Voice Mail F Start at End of String for Go to Voice Mail Enabled Location of Mailbox Numbe...

Page 16: ...essage waiting lights may not work Try setting the protocol of the Serial link to odd parity seven data bits and two stop bit 1200 7 O 2 7 0 CONSIDERATIONS ALTERNATIVES The following items should be c...

Page 17: ...x 2400 w Direct Serial LinkC o n f i d e n t i a l P a g e 1 7 The above information is provided by Octel Communications Corporation as a guide See disclaimer on page 1 O c t e l C o m m u n i c a t i...

Reviews: