CHAPTER 3
NDA-24219
Page 44
Revision 2.0
NAP-200-005
Sheet 1/4
Connection of Battery
1.
BATTERY CONNECTION
CAUTION 1:
24V batteries must be used in this system.
CAUTION 2:
If battery terminals (+, –) contact with the module under connecting the battery cable to the PZ-
PW86/PW112 card, the PZ-PW86/PW112 card or the BWB may be broken. Therefore, the in-
staller must perform work in accordance with the following steps when mounting or removing
the batteries.
•
When mounting batteries:
(1) Connect the battery cable to the batteries.
(2) Mount the batteries into the appointed position of the PIM.
(3) Connect the battery cable to the PZ-PW86/PW112 card.
•
When removing batteries:
(1) Disconnect the battery cable from the PZ-PW86/PW112 card.
(2) Remove the batteries from the PIM.
Standard Battery
Internal Battery
:
GS type PX 12026
Optional Battery
External Battery
:
YUASA
MATUSHITA
type
type
NPH-3.2-12
LCR-12V-3.4NE
These batteries will provide 30 minutes of battery backup. They will
not fit within the NEAX1000 PIM.