![NEC NEAX 1000 IVS System Manual Download Page 137](http://html.mh-extra.com/html/nec/neax-1000-ivs/neax-1000-ivs_system-manual_251362137.webp)
NDA-24219
CHAPTER
3
Page 123
Revision 2.0
NAP-200-010
Sheet 6/7
System Initialization and
System Data Entry
(2) Programming Procedure for Pushbutton Calling
DESCRIPTION
DATA
Assign the Card Number of internal PB Receiver to
the LEN No. 0124.
Note:
When using the internal PB Receiver on
the MP card, assign the Card No. E200-
E203 to the LEN No. 0124.
If resident load is used, PB Receiver ports
(E200-LENS 0124) are automatically as-
signed.
(1) LEN: 0124
(2) E200-E203 (PB Receiver No.)
Assign the type of telephone set (DTMF) to DTMF
Stations.
This data assignment is not required for Multiline
Terminal station.
.
YY = 00
(1) X-XXXX (Station No.)
(2) 2 : DTMF Telephone set
Assign PB Receivers for use with DTMF
Stations.
.
Y = 0 (Make Busy)
(1) XX X
(2)
:Make Busy Cancel
.
Y = 1 (Purpose)
(1) XXX (Ditto to Y = 0)
(2) 1
:For both DTMF station and Tie Line/
DID
START
CM10
A
CM12
CM45
INITIAL
Circuit No. 0-3
Card No. 00-03 assigned by
CM10(E200-E203)