CHAPTER 3 NDA-24219
Page 42
Revision 2.0
NAP-200-004
Sheet 1/2
PWR CA-A and BUS Cable Connection
(1) When the system is two PIM configuration, connect the PZ-PW86/PZ-PW112 Cards to each other using
PWR CA-A cables, as shown in
Figure 004-1 Connection of PWR CA-A Cables
PIM1
PIM0
PZ-PW86/
BATT2
BATT1
PZ-PW86/
BATT2
BATT1
Note:
For details of battery connection, see NAP- 200-004.
PWR CA-A
PZ-PW112
PZ-PW112
PIM1
PIM0
PZ-PW86/
BATT2
BATT1
PZ-PW86/
BATT2
BATT1
PWR CA-A
PZ-PW112
PZ-PW112
TO BATTERY
TO BATTERY
TO BATTERY
•
When using internal batteries
•
When using external batteries