NDA-24219
CHAPTER
3
Page 39
Revision 2.0
NAP-200-003
Sheet 10/12
Installation of Main Equipment
Figure 003-7 Cable Connection on PZ-PW86/PW112 (Continued)
PZ-PW112
MJ
MN
ON
GND
Note
FG
–27V
PWR CNT CA-A/
TO PWR1
AC CORD-A
TO AC MAINS INPUT
TO
CONNECTOR
TO AUXILIARY
BATTERY CONNECTOR (BATT2)
ON
OFF
EQUIPMENT
GREEN
WHITE
BLACK
FRAME GROUND
Note:
If GND (Signal GND) has to be
separated from FG (Frame GND),
remove the link between GND and
FG terminal
–
O
TERMINAL ON THE
TO OTHER PZ-PW112
PWR CA-A
TO BATTERY OR
OTHER PZ-PW112
BATTERY CONNECTOR (BATT1)
BATTERY CABLE/PWR CA-A
CHASSIS
• PZ-PW112
TO PWR0A CONNECTOR
POWER OUTPUT
CABLE (+5V, –27V,E)
PWR CNT CA-C