CHAPTER 3 FUNCTIONAL OUTLINE
PRELIMINARY
NEC confidential and Proprietary
84
3.4.3 Alarm management
(1) Alarm detection
When the
µ
PD98413 detect the specific alarm, the corresponding alarm is detected automatically and
notified by the corresponding register bits. The detection alarm is as follow.
Detection
alarm
Detect condition
OOF
LOF
When LOS is detected.
Line AIS
When LOS or LOF is detected.
Path AIS
When LOS, LOF or Line AIS is detected.
OCD
LCD
When LOS, LOF, Line AIS, LOP or Path AIS is detected.
(2) Protection of the alarm detection
When the
µ
PD98413 detect the specific alarm, the mPD98413 is protected the alarm detection and
not detect corresponding alarm. And if the corresponding alarm is in detecting condition, that alarm is
terminated automatically. The protection and termination alarm is as follow.
Termination
alarm
Terminate condition
Section TIM
Section TIU
When LOS and OOF is detected.
Line RDI
PSBF
When LOS and LOF is detected
LOP
When LOS, LOF or Line AIS is detected.
Path RDI
Path PLM
Path UNEQ
Path TIM
Path TIU
When LOS, LOF, Line AIS, LOP or Path AIS is detected.
Summary of Contents for NEASCOT-P65
Page 4: ...PRELIMINARY NEC confidential and Proprietary 4 MEMO ...
Page 8: ...PRELIMINARY 8 MEMO ...
Page 35: ...PRELIMINARY NEC confidential and Proprietary 35 MEMO ...
Page 135: ...CHAPTER 4 INTERFACES PRELIMINARY NEC confidential and Proprietary 135 ...
Page 166: ...CHAPTER 5 REGISTERS PRELIMINARY NEC confidential and Proprietary 166 5 2 Register summary ...
Page 167: ...CHAPTER 5 REGISTERS PRELIMINARY NEC confidential and Proprietary 167 ...
Page 168: ...CHAPTER 5 REGISTERS PRELIMINARY NEC confidential and Proprietary 168 ...
Page 303: ...CHAPTER 5 REGISTERS PRELIMINARY NEC confidential and Proprietary 303 MEMO ...
Page 317: ...CHAPTER 6 JTAG BOUNDARY SCAN PRELIMINARY NEC confidential and Proprietary 318 MEMO ...