120
Appendix
5-2. Error Code List
Please inquire your dealer/distributor about action to be taken for each error code.
Error
Code
Error message
Description
5
Light Unlit
The light source is not on.
12
EEPROM R Fail
E2PROM data read error is detected.
13
Interlock Fail
Interlock is activated.
15
EEPROM W Fail
E2PROM data write error is detected.
120
DLP Ack Fail
ICP failed operation. It could be caused by configuration files lost, disk
space issue, or DISKCHIP corruption issue.
121
Lens Fail
Lens unit control error.
135
FMT FPGA Boot Fail
FMT FPGA failed to boot.
136
FMT FPGA System Fail
FMT FPGA failed to system startup.
137
LoginMgr Comm Fail
Login Manager communication error.
138
LoginMgr Boot Fail
Login Manager failed to boot.
141
DLP CommE Fail
No communication with the ICP board and DCC.(Communication I/F is
Ethernet)
143
FMT Board Config Mismatch
DPSW setting of FMT board is inappropriate.
165
GPI MACRO(n) Selection Invalid
Selection of preset button (n) through GPI is invalid because metadata is
enabled.
* This message would be shown on Log, not on LCD.
166
GPI Control Invalid
Projector control through GPI is invalid because projector is busy.
* This message would be shown on Log, not on LCD.
177
Tamper Fail
Service door tamper switch of projector is open.
178
Marriage Tamper Fail
Marriage tamper switch of projector is open.
190
The Validity has expired.
The time limit for use of the projector has expired.
* In cases when the validity setting has been configured with the projector.
191
Different Serial Number
There is a mismtach in the serial number of the main unit internally saved
on the projector.
192
Model Code Mismatch
There is a mismtach in the model code of the main unit internally saved on
the projector.
230
Router Fail
Failed to control router.
271
IMB:SD Tamper Terminate
Terminated service door tamper event latched by IMB.
* This message would be shown on Log, not on LCD.
301
System Error
ICP system status error.
302
Self Test Error
ICP system status error.
To recover the issue, update ICP to higher than Prod3.0 or equal. If that
can not remove the issue, remove and reseat the ICP board.
303
Install Release Package Error
ICP system status error.
It could be caused by disk space issue or DISKCHIP corruption issue.
304
Load Release Package Error
ICP system status error.
It could be caused by disk space issue or DISKCHIP corruption issue.
305
Key Error
ICP system status error.
306
Certificate Error
ICP system status error.
329
Sequence Data File Mismatch
ICP system status error.
331
Flash Checksum Error - Sequence Data
ICP system status error.
333
Satellite Hardware Mismatch
ICP system status error.
334
FSB Flash Update Error
ICP system status error.
335
Red Satellite Reports Reset
ICP system status error.
336
Red Satellite Serial Link Error
ICP system status error.
337
Red Satellite Firmware Configuration Error
ICP system status error.
342
Green Satellite Reports Reset
ICP system status error.
343
Green Satellite Serial Link Error
ICP system status error.
Summary of Contents for NC2041L
Page 1: ...NC3541L NC2041L NP NC3541L NP NC2041L ...
Page 8: ...Label A Risk Group Lamp Safety Label ...
Page 9: ... Label B Laser Explanatory Label Label C NP NC3541L ...
Page 10: ... Label C NP NC2041L Label D Label E ...
Page 48: ......
Page 108: ... NEC Display Solutions Ltd 2017 Ver 1 0 7 17 ...