8-22 System Upgrade
Removing DIMM
Follow the procedure below to remove the DIMM.
IMPORTANT:
This server works only when there are at least two DIMMs installed.
1.
Shutdown OS.
The system turns off automatically.
2.
Disconnect the power cords from the outlets.
3.
Remove the CPU/IO module referring to page 8-12.
4.
Remove three screws (two on the front and one on the rear), and remove the top cover of
the CPU/IO module
5.
Remove the air duct.
Air duct