![NEC N8800-149F User Manual Download Page 170](http://html1.mh-extra.com/html/nec/n8800-149f/n8800-149f_user-manual_4278803170.webp)
7-6 Troubleshooting
On-screen error message
Cause
Action
0B96 BMC SDR Repository
failure
SDR repository within BMC
is faulty.
0B97 BMC SEL device failure
SEL repository within BMC is
faulty.
0B98 BMC RAM test error
BMC RAM is faulty.
0B99 BMC Fatal hardware
error
BMC FPGA is faulty.
0B9A BMC not responding
BMC device is faulty.
Replace the CPU/IO module.
0B9B Private I2C bus not
responding
I2C bus is faulty.
If turning AC power off and on
does not help, replace the
CPU/IO module or the system
backboard.
0B9C BMC internal exception
0B9D BMC A/D timeout error
BMC device is faulty.
Replace the CPU/IO module
0B9E SDR repository corrupt
SDR data is faulty.
If updating SDR does not solve
the issue, replace the CPU/IO
module.
0B9F SEL corrupt
SEL repository within BMC is
faulty.
Replace the CPU/IO module
0BA0 SDR/PIA mismatched.
SDR, PIA must be
updated.
SDR and PIA data do not
match.
If updating SDR/PIA does not
solve the issue, replace the
CPU/IO module.
0BB0 SMBIOS - SROM data
read error
•
I2C bus is faulty.
•
SROM is faulty.
•
BMC is faulty.
0BB1 SMBIOS - SROM data
checksum bad
Data within SROM is faulty.
If turning AC power off and on
does not help, replace the system
backboard.
0BC0 POST detected startup
failure of 1st Processor
CPU is faulty.
0BC1 POST detected startup
failure of 2nd Processor
Replace the CPU.
8100 Memory Error detected
in DIMM group #1
Replace DIMM slot 1 and 2.
8101 Memory Error detected
in DIMM group #2
Replace DIMM slot 3 and 4.
8102 Memory Error detected
in DIMM group #3
Replace DIMM slot 5 and 6.
8103 Memory Error detected
in DIMM group #4
Replace DIMM slot 7 and 8.
8104 Memory Error detected
in DIMM group #5
Replace DIMM slot 9 and 10.
8105 Memory Error detected
in DIMM group #6
DIMM is faulty.
Replace DIMM slot 11 and 12.
8120 Unsupported DIMM
detected in DIMM
group #1
8121 Unsupported DIMM
detected in DIMM
group #2
Non-supported DIMM is
mounted.
Check the supported DIMM and
replace the DIMM. If replacing the
DIMM does not help, replace
CPU/IO module.
Summary of Contents for N8800-149F
Page 18: ...ix THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 45: ...General Description 2 9 Rear View R320a E4 R320a M4...
Page 80: ...3 14 ESX Operation and Configuration This page is intentionally left blank...
Page 96: ...4 16 System Configuration IMPORTANT Wake On LAN environment is unavailable on ESX4 0...
Page 97: ...System Configuration 4 17 Security Move the cursor onto Security to display the Security menu...
Page 110: ...4 30 System Configuration Exit Move the cursor onto Exit to display the Exit menu...
Page 122: ...4 42 System Configuration This page is intentionally left blank...
Page 150: ...5 28 Installing and Using Utilities This page is intentionally left blank...
Page 215: ...System Upgrade 8 31 Riser Card PCI 3 PCI 4 PCI 1 PCI 2 R320a E4 PCI 1 PCI 2 R320a M4...