125
31.
Hold
Ctrl
and click the two DGs in the Configuration column to select.
32.
Specify the necessary parameters in Virtual Disk column.
33.
Enter "YYYYY*2" (the maximum size allowed for spanning of RAID1) in "Select
Size" field.
Notice
For disk capacity, enter the sum of "the maximum size allowed for RAID1".
To configure the spanning of RAID5, create several RAID VD, and enter the
sum of "the maximum size allowed for RAID5".
(In the example below, enter "YYYYY * 2 MB" because the maximum size
allowed for RAID1 is YYYYY MB.)
Spanning of RAID1
Value to be entered = the maximum size allowed for a single RAID1 VD
* number of VDs to be spanned
Spanning of RAID5
Value to be entered = the maximum size allowed for a single RAID5 VD
* number of VDs to be spanned
34.
Click [Accept] at the lower center of the screen.