143
(3) HDD failed
Contact your service representative.
(4) Rebuild cannot be executed.
8
Is the capacity of the HDD to be rebuilt rather small, isn
’
t it?
Use a disk having the same capacity as the defected HDD.
8
Is the RAID level of the virtual disk RAID0, isn
’
t it?
Rebuild is not possible because of no redundancy in RAID0. Replace the
defected HDD and create the virtual disk again.
(5) Consistency Check is disabled.
8
Is the virtual disk degraded?
→
Replace the defected HDD and execute Rebuild.
8
Is the RAID level of the virtual disk RAID0, isn
’
t it?
→
Consistency Check is not possible because of no redundancy in RAID0.
(6) The additional battery is not recognized, or POST displays the message below.
8
Is the cable connected between the battery pack and DIMM?
Connect the cable correctly.
If the additional battery is not recognized still despite the above actions, the
battery may be defected.
Contact your service representative.