4. RAID System Configuration
Express5800/R120d-1E, R120d-2E Maintenance Guide
97
Chapter 2 Convenient Features
4.2
Menu Tree
: Selection and execution parameter
z
: Setting
parameter
•
: Data
display
¡
: Can be set or modified after a Virtual Drive is created
(1/2)
Menu
Description
Configure
Specify configuration settings
Easy Configuration
Set a configuration using fixed values
New Configuration
Set a new configuration
View/Add Configuration
Add or view a configuration
Clear Configuration
Clear the configuration data
Select Boot Drive
Select a Virtual Drive to be booted
Initialize
Initialize the Virtual Drive
Objects
Set up various objects
Adapter
Set up the RAID Controller
Sel. Adapter
Select an adapter
z
Rebuild Rate
30 (Rebuild IO Rate)
z
Chk Const Rate
30 (Check Consistency IO Rate)
z
FGI Rate
30 (Foreground Initialize IO Rate)
z
BGI Rate
30 (Background Initialize IO Rate)
z
Disk WC
Off (Write Cache setting on Adapter. This setting is not used
by LSI Software RAID)
z
Read Ahead
On (Read Ahead setting on HDD.)
z
Bios State
Enable (The setting of whether system loads the LSI
Software BIOS or not.)
z
Cont on Error
Yes (The setting of whether system stops on POST when an
error issued on LSI Software BIOS.)
z
Fast Init
Enable (The setting of Fast Initialize of Full Initialize.)
z
Auto Rebuild
On (The setting of whether to Rebuild automatically or
manually, when the HDD was fail.)
z
Auto Resume
Enable (The setting of whether to continue at the time of the
next execution, when processing is interrupted.)
z
Disk Coercion
1 GB (The accommodating boundary size when the HDDS of
different size are configured.)
z
Factory Default
Reset to the default values
Virtual Drive
Operate a Virtual Drive
Virtual Drives
Select a Virtual Drive (when multiple Virtual Drives exist)
Initialize
Initialize the Virtual Drive
Check Consistency
Check Virtual Drive redundancy
View/Update Parameters
View the Virtual Drive information
•
RAID
View the RAID level
•
SIZE
View the Virtual Drive capacity
•
Stripe SIZE
View the stripe size
•
#Stripes
View the number of Hard Disk Drives in the Virtual Drive