4. RAID System Configuration
Express5800/R120d-1E, R120d-2E Maintenance Guide
107
Chapter 2 Convenient Features
4.3.4
Executing a Consistency Check
Run the LSI Software RAID Configuration Utility
Execute a Consistency Check
Exit the LSI Software RAID Configuration Utility
1. Run the LSI Software RAID Configuration Utility.
2. Select
Check Consistency
from the TOP menu.
The Virtual Drives screen appears.
3. Move the cursor to the Hard Disk Drive to be checked for consistency, and then press the space key to
select it. The Virtual Drive is selected.
4. Press the <F10> key while the desired Virtual Drive is selected.
5. When the confirmation message for execution appears, select [Yes
]
to start a Consistency Check.
The Consistency Check completes when the
Completed
progress bar on the CC Under Progress
screen becomes 100%.
6. Press the <Esc> key to return to the TOP menu screen, and then exit the LSI Software RAID
Configuration Utility.
Important
•
Be sure to execute a Consistency Check after creating a configuration.
•
Do not execute a Consistency Check for RAID0.