English−15
Mounting (for Trained Installers)
Carefully inspect the location where the unit is to be mounted. Not all walls or ceilings are capable of supporting the weight
of the unit. The weight of this monitor is provided in the specifications (see
). Product warranty does not
cover damage caused by improper installation, re-modeling, or natural disasters. Failure to comply with these recommendations
could result in voiding the warranty.
To ensure safe installation, use two or more brackets to mount the unit. Mount the unit to at
least two points on the installation location.
Allow for adequate ventilation or provide air conditioning around the monitor, so that heat can
properly dissipate away from the monitor and from the mounting equipment.
Please note the following when mounting on a wall or ceiling:
• We recommend mounting interfaces that comply with UL1678 standard in North America.
• For detailed information, refer to the instructions included with the mounting equipment.
We strongly recommend using the screws as shown below.
If using screws longer than below mentioned, check the depth of the hole.
Screw Size
Bracket Hole
No Thread
Recommended Fasten Force
(A)
(B)
(C)
(D)
M8 (4 pcs)
16~18 mm
≤
Ø
12 mm
6 mm
950-1600 N•cm
NOTE:
When used in a video wall configuration for a long time, slight expansion of the monitors may happen due to
temperature changes. It is recommended that a gap of over one millimeter is kept between adjacent monitor edges.
> 1 mm
> 1 mm
A
Unit
C
Washers
Mounting
Bracket
No thread
D
Thickness of
bracket and
washers
B
Gap
Gap