4-72 Configuring Your Server
6.
Select a DG to define VD from "Array With Free Space" frame, then click [Add to SPAN].
The DG is defined in the "Span" field to the right.
7.
After the Span has been defined, click [Next] at the lower right of the screen.
IMPORTANT:
To configure RAID0, 1, 5, or 6, perform Span Definition to a single
DG only. If you need to perform Span Definition to several DGs,
define VD for the first DG, then select the next DG to define VD.
To configure RAID10 or 50, select several DGs containing the same
number of HDDs for Span Definition.
Span Definition cannot be performed to DGs containing the
different number of HDDs.