1. Installing Internal Optional Devices
Express5800/T120d User’s Guide
91
Chapter 2 Preparations
1.13.2
Removal
(1) 2.5-inch HDD cage
The server can contain up to three 2.5-inch HDD cages. Remove cages starting from the bottom bay.
Remove 2.5-inch HDD cage in the following procedure.
1.
Refer to steps 1 to 7 in
Chapter 2 (1.3 Overview of Installation and Removal)
for preparations.
2.
Remove hard disk drives from 2.5-inch HDD cage.
3.
Disconnect SAS/SATA cable, SGPIO cable, and power cable.
4.
Remove screws that secure the 2.5-inch HDD cage.
5.
Pull out 2.5-inch HDD cage from the server.
6.
To use the server with 2.5-inch HDD cage removed, attach blank covers using screws.
Important To maintain cooling effect in the server, be sure to attach blank covers.
(2) 3.5-inch HDD cage
The server can contain up to two 3.5-inch HDD cages. Remove cages starting from the bottom bay.
Remove 3.5-inch HDD cage in the following procedure.
1.
Refer to steps 1 to 7 in
Chapter 2 (1.3 Overview of Installation and Removal)
for preparations.
2.
Remove hard disk drives from 3.5-inch HDD cage.
3.
Disconnect SAS/SATA cable, SGPIO cable, and power cable.
4.
Remove screws that secure the 3.5-inch HDD cage.
5.
Pull out 3.5-inch HDD cage from the server..
6.
To use the server with 3.5-inch HDD cage removed, attach blank covers using screws.
Important To maintain cooling effect in the server, be sure to attach blank covers.
7.
If you install another HDD cage, remove two guides.