2. System BIOS Setup
Express5800/T120d User’s Guide
143
Chapter 3 Setup
2.4
Cases that Require Configuration
Only if a case applies to any of following cases, use the SETUP utility to change a parameter which was
configured as shipping defaults. Other than cases described below, do not change the settings. A list of
SETUP parameters and shipping defaults are described in
Chapter 2 (1. System BIOS)
in "
Maintenance
Guide
".
Category
Description
To be changed
Remark
Basic
Change date and time
Main
→
System Date
Main
→
System Time
Configurable on OS
Turn ON NumLock feature at
power-on
Boot
→
Bootup Numlock State
→
ON
Hide display of logo during
POST
Boot
→
Quite Boot
→
Disabled
By pressing the <Esc> key,
prevent the display of the logo.
Memory
Add or change DIMM
Advanced
→
Memory Configuration
→
Memory Retest
→
Yes
After rebooting,
Memory
Retest
changes
No
automatically.
Use memory RAS feature
Advanced
→
Memory Configuration
→
Memory RAS Mode
→
set RAS mode
appropriately
Some of RAS features may not
be used depending on DIMM
configuration.
Optional
board
Disable Option ROM Scan of
installed option board
Advanced
→
PCI Configuration
→
PCI
Device Controller and Option ROM
Settings
→
PCIXX Slot Option ROM
→
Disabled
XX is PCI slot number of the
option board
Boot
Change the boot order of
devices
Boot
→
Boot Option Priorities
→
Change the boot priority
When you use
EXPRESSBUILDER, set
CD/DVD to the highest priority.
Use remote power on feature
(via modem)
Advanced
→
Advanced Chipset
Configuration
→
Wake On Ring
→
Enabled
Use remote power on feature
(via RTC alarm)
Advanced
→
Advanced Chipset
Configuration
→
Wake On RTC Alarm
→
Enabled
Use console redirection feature
Advanced
→
Serial Port Configuration
→
Console Redirection Setting
→
Change respective setting.
Security
Set a password
Security
→
Administrator Password
→
Set a password
Security
→
User Password
→
Set a
password
If password is set, a message
to enter password is displayed
at next time SETUP is
launched.
Restrict bootup by entering
password
Security
→
Password on Boot
→
Enabled
Can be selected when
password is set.
UPS
Powerlink
When the server is supplied
with power from UPS, always
turn on the power.
Server
→
Power Control
Configuration
→
AC-LINK
→
Power
On
If it is turned off by using
POWER switch, leave it OFF
even when UPS supplies
power.
Server
→
Power Control
Configuration
→
AC-LINK
→
Last
State
Keep the power OFF even
when UPS supplies power.
Server
→
Power Control
Configuration
→
AC-LINK
→
Stay off