Maximum Current:
250 mA
Acoustical characteristics meet Electronic Industry Association
(EIA) standard proposal SP-1286 and standard EIA RS-470.
J
Single Line Telephone
Standard 2500 Set:
500 type network
Nominal Current:
35 mA
Ring Signal:
56 Vac RMS @ 20 Hz
J
SLT(1)-U( ) ADP
Standard 2500 Set:
500 type network
Nominal Current:
30 mA
Ring Signal:
56 Vac RMS @ 20 Hz
J
AP(A)-R Unit
Standard 2500 Set:
500 type network
Nominal Current:
30 mA
J
AP(R)-R Unit
Standard 2500 Set:
500 type network
Nominal Current:
30 mA
Ring Signal:
56 Vac RMS @ 20 Hz
5.5.5
Series i Terminals
The voltage and current information for the D
term
Series i Multiline
Terminals are listed below:
J
Multiline Terminal (Series i)
Voltage:
-11 ~ -48 Vdc
Maximum Current:
250 mA
Acoustical characteristics meet Electronic Industry Association
(EIA) standard proposal SP-1286 and standard EIA RS-470.
J
Voltage, current, and ring signal information for Single Line
Telephone equipment, AP(A)-R Unit, and AP(R)-R Unit are the
same as those listed in the previous paragraph.