7 - 15
___________________________________________________________________________________
___________________________________________________________________________________
6.6
External Page
Two external page zone/door box circuits are provided by each PGD(2)-U10
ADP installed. Each Door Box/external page circuit provides a dry relay
contact. The external page speakers provided by the
PGD(2)-U10 ADP
are
1~8. The relays on the
PGD(2)-U10 ADP
are numbered 1~8. Refer to Paging,
External in the Electra Elite IPK II Features and Specifications Manual for
additional details.
A PGD(2)-U10 ADP circuit used for External Paging cannot be used for an
analog Door Box.
6.7
Connecting to the PGD(2)-U10 ADP
1.
Make sure the jumper in the
PGD(2)-U10 ADP
for the channel is set
).
2.
If a line cord was not previously connected to the
PGD(2)-U10 ADP
,
complete Steps 3~6. Otherwise, skip to Step 7.
3.
Install a modular jack for each
PGD(2)-U10 ADP
. Run one-pair 24 AWG
station cable from the crossconnect block to a modular jack. Ground the
unused pair.
4.
Terminate the extension leads to GRN/RED of the modular jack.
Terminate the unused leads to the jack.
5.
Install bridging clips as required.
6.
Plug a modular line cord from the mod jack to the CN1 connector on the
PGD(2)-U10 ADP
.
7.
Connect the two-conductor station cable from the CN5 connector in the
PGD(2)-U10 ADP
to the external relay/external page.