Electra Elite IPK II
Document Revision 3
System Hardware Manual
6 - 25
___________________________________________________________________________________
___________________________________________________________________________________
5.2.2
Installation
Basic Port Package
A maximum of seven BRT(4)-U20 ETUs can be installed in any
interface slot in the system. The system limitation is 64 trunk and
station ports combined.
The maximum number of BRT(4)-U20 ETUs depends on other trunk
cards installed. This ETU shares the total number of CO/PBX lines
in the system.
Calculating maximum capacity is based on the system having a
minimum of eight Electronic Station Interface (ESI) ports, four trunk
ports and a PKUII-U Unit installed.
Expanded Port Package
A maximum of 23 BRT(4)-U20 ETUs can be installed in any interface
slot in the system. The system limitation is 200 trunks.
The maximum number of BRT(4)-U20 ETUs depends on other trunk
cards installed. This ETU shares the total number of CO/PBX lines
in the system.
Calculating maximum capacity is based on the system having a
minimum of eight Electronic Station Interface (ESI) ports, four trunk
ports and a PKUII-U Unit installed.
5.2.3
Switch Settings
SW1 is the reset switch.
DSW1 is used for maintenance. Normal operation is all three Off.
5.2.4
Jumpers
CN101 and CN102
Set the 100
Ω
termination to On or Off for Circuit 1. Jumper Pins 1
and 2 are shorted together at the factory to turn on the 100
Ω
terminal.
CN201 and CN202
Set the 100
Ω
termination to On or Off for Circuit 2. Jumper Pins 1
and 2 are shorted together at the factory to turn on the 100
Ω
terminal.
Switches DSW1~3
ON: IPK II BRT Mode
OFF: IPK BRT Mode