AC power supply cable
- Be sure that the cable used to connect the main unit with the AC power supply equipment
of the building has a core thickness of 6 AWG, 8 AWG or 14 mm
2
according to the
requirements of the country where the unit is installed, and that the cable core is made of
copper.
- Use a round type UL-listed solderless terminal for the section connected to the main unit.
In addition, when clamping this terminal with the cable, use an UL listed tool.
Mounting terminals
The specifications of the cable installation terminal is indicated below.
Power terminal
JIS
IEC/EN
UL
CSA
Complying wire (using
solderless terminal)
14 mm
2
14
mm
2
AWG 6 or
AWG 8
AWG 6 or
AWG 8
Terminal screw
M6 x 15
Tightening torque
2.5 to 3.5 Nm
Grounding terminal
JIS
IEC/EN
UL
CSA
Complying wire (using
solderless terminal)
14 mm
2
14
mm
2
AWG 6 or
AWG 8
AWG 6 or
AWG 8
Terminal screw
M6 x 15
Tightening torque
2.5 to 3.5 Nm
Crimping terminals
The size of the crimping terminals that are suitable for the AC power supply cable
attachment points of the projector are as indicated below.