WALL - Technical Handbook
Single button presence (one-button indication)
Select if the unit should use single button or bouble button Presence.
• No, function off (default)
• Yes, function on
Auto ready time (minutes), (0=off)
Enter the time in the interval of 0-255 minutes, where 0=Off.
5.13.3 Technical alarms
Radio test alarm interval (h) (0=off)
This parameter and the next are used to monitor the unit. Every 9 hours
(configurable; 1-255, 0=off) the WALL unit transmits a
Radio test alarm
and expects
to receive an acknowledgement from a monitoring device. If no acknowledge is
received, the unit retries until the “Number of missed ACK” is reached. It then stops
sending the
Radio test alarm
, i.e. the unit is in
Sleep mode
. When in sleep mode, any
other alarm type that is sent by the unit and acknowledged will restart the “Radio
test alarm” interval.
Default = 9
Number of missed ACK before sleep (0=never)
Default = 19
Battery check interval (h) (0=off)
When the unit is powered only by batteries it can be set to check the status of the
batteries at intervals (1-255 hours, 0=off). When powered by 24 V
DC
this interval is
fixed to 2 hours.
Default = 23
Check battery in 24V mode
When powered by 24 V
DC
and no batteries are present the check battery function
must be disabled to prevent the unit from sending “Battery alarm”.
• Yes, function on
• No, function off (default)
5.13.4 Technical info
These are read only values.