6
[Date]
Start Mode
This field configures the mode the module should utilize on boot. For NCD
Devices only Data Mode is recommended.
Socket Type
TCP Server MUST BE SELECTED
.
If you change this setting from UDP or TCP Client setting, power cycle the
board before trying to connect to N-Button Software.
This field configures
how the module handle’s socket connections. The options are TCP Server,
TCP Client, or UDP. In TCP Server mode the module will boot up and begin
listening for socket connections from software applications
Remote Host
This field is only applicable when Socket Type is set to TCP Client or
UDP. This field configures the IP address the module should attempt to
establish a connection to on start up.
Remote Port
This field is only applicable when Socket Type is set to TCP Client or
UDP. This field configures the Port the module should attempt to establish
a connection to on start up.
Local Port
This field is only applicable when Socket Type is set to TCP Server. This
field configures the Port the module will accept TCP client connections on.
UART Setting
These fields configure how the module handles serial communication with
the main control board it is plugged into. NCD Staff test and configure
every module prior to shipment so all of these settings should be correct
when you receive your product. If any changes are made to these settings
it will be necessary to make configuration settings to the main host control
board the module is installed in as well.
Save Settings/Reset
Once settings are entered and configured as desired click the Save Settings
Button. This will store settings into the Gen 3 module, however these new
settings will not be utilized until the next power up of the module so if you
would like to implement the new settings now click the Reset button after
clicking the Save Settings Button.