![NBS Technologies ImageMaster D-40 Operation Manual Download Page 26](http://html1.mh-extra.com/html/nbs-technologies/imagemaster-d-40/imagemaster-d-40_operation-manual_3663857026.webp)
D-40 Operation Manual
4-7
Chapter 4 Page 7
Creating Layouts
Figure 4-7:
Font Field Type Overview
Type: Font
Font Name
X coordinate
Destination ID
Justify from - -
Left / Center / Right
Rotation - -
Horizontal / Vertical / Reverse Hor / Reverse Vert
Transfer - -
Off / Destination on / Source on
Transfer Type - -
Normal / Name
Y coordinate
Source ID
Accept - -
Fixed / Variable / Host
Fixed Text
Max. Char.
Accept - - Fixed / Variable / Host
Fixed Text
Max. Char.
Pad Char. - - None / Space
Auto Advance - - No / Yes
Prompt - - (35 Char. Max)
Min. Characters
Max. Characters
Default Text - - (45 Char. max)
Allow - - Digits / Alpha / All
Mod 10 - - No / Yes
Increment by - (3 digit max)
Strip Space - - Yes / No
Card Side
Top / Bottom
UTILITIES / FILE / CREATE or EDIT / LAYOUT /
FONT MENU