Chapter3. Cash Dispenser Error Code
3-14
© 2009
Nautilus Hyosung Inc.
All Rights Reserved.
Error Code
Description
Trouble shooting
40039
Gate operation sensor (CS3)
error before initial recovery
1. Initialize after removing notes or
dust over Gate
2. Check CS3 Sensor BKRT
3. Check CS3 Sensor Cable
4. Exchange Sensor after abnormal
operating CS3 Gate detecting
Sensor
5. Exchange Reject Solenoid 1
40036
CS2 & CS13 dark detection
during initializing or dispense
reserved operation.
1. Remove the remaining notes and
foreign objects at the position of
the CS2 & CS13 sensor
2. Check if the CS2& CS13 sensor
cable is disconnected
3. Exchange sensor if error occurs
after checking CS2 & CS13 sensor
operation
40034
Error of double detecting module
including sensor (CS5_1
/CS5_2) during dispensing bills
1. Check CDU Board Segment.
2. Initialize
3. Read dat
a of ‘Read Double
Sensor’ Command
40032
Error of Gate Solenoid module
1. Check if the Gate Solenoid cable
is disconnected
40031
Error of Reject Gate Solenoid
module
1. Check if the Reject Gate
Solenoid cable is disconnected
40030
Main motor speed error.
1. Initialize
2. Check Main Motor Encoder Slit
3. Initialize after Power On/Off
4. Check Encoder Sensor CS8
BRKT
5. Check CS8 Sensor Cable
6. Change Main Motor Encoder Slit
Sensor CS8
4002B
CS11A, CS11B & CS13 dark
detection during initializing or
dispense reserved operation.
1. Remove the remaining notes and
foreign objects at the position of
the CS11A/B & CS13 sensor
2. Check if the CS11A/B & CS13
sensor cable is disconnected
(CDU Board CN10 #1~4).
3. Exchange sensor if error occurs
after checking CS13 sensor
operation