Important Notes on Installation
Water Testing
—
Because of variances in water quality, if your water source
is a well, please contact Support at 1-800-428-9419 before installation. You
should have your water tested by a certified water laboratory.
Water Shutoff
—
Naturally Filtered will not be held liable for damages,
including any and all water damage caused by this product or its plumbing.
It is recommended that the homeowner consider the use of an electronic
water shut off system (such as WaterCop –
http://www.watercop.com
).
See
Warning page 9.
Drainage
—
The MG-10 requires a drain or drain field (dependant on local
plumbing code) for the unit to dispose of water during its regeneration cycle.
The drain or drain field must be able to disburse a minimum of 5 GPM.
Water Pressure
—
Water pressure should not exceed 100 psi. If your water
pressure is close to 100 psi, you must have a plumber install a pressure
regulator on your main line before the MG-10.
Existing Plumbing
—
The condition of the existing plumbing should be
free from lead, lime, and iron buildup. Piping that is heavily built up with lead,
lime, and/or iron should be replaced. All new plumbing should be performed
in accordance with local plumbing codes.
Electric Code
—
An uninterrupted alternating current 110V (AC), 60 Hz,
supply is required. Unit must be installed to meet the current National Elec-
tric Code. A ground-fault-interrupt (GFI) outlet is recommended to protect
your unit.
Install Checklist
- Before you Start
Parts Checklist
1. Bypass Valve
2. 1” Male NPT Adapter
3. O-ring Couplings (2)
4. Mesh Bag
5. Barbed Drain Elbow
4
Assembly
• Rear of Housing
Drain Line Outlet
• Elbow attaches here
Main Supply Connection
• Water supply OUT
• Water supply IN
Step 1 - Barbed Drain Elbow
Install Barbed Drain Elbow into Drain
Line Outlet (Teflon tape may be used).
This step must be completed prior to
connecting O-ring Couplings.
Step 2 - O-ring Couplings
Install
both
O-ring Couplings
to the Main Supply Connection
channels (one on right or OUT
channel shown here).
Step 4 - Secure Complete Manifold
Add 1” Male NPT Adapter and
secure to manifold by tightening
metal locking clamps.
Step 3 - Bypass Valve
Attach the Bypass Valve Assembly to
the Control Valve over the O-ring Cou-
plings just installed and lock in place
using the metal locking clamps.
Inlet & Outlet Bypass Valves Closed
In this position your MG-10 is in
full by-pass mode.
Inlet and Outlet Bypass Valves Open
Here bypass valves are open. This
is the normal service position for
the MG-10.
Tap
Water
IN
Filtered
Water
OUT
Assembling Bypass Valve