ENGINEERING STANDARDS

Rosedale Products, Inc.

IOM

Issue Date: 29MAY96

3730 West Liberty Road

D6150STD.WP6

Revision:  

Ann Arbor, MI 48103

n:\iom\

Revision Date:  

Specification No.

7.3.4

PAGE:  1 of 6 

INSTALLATION, OPERATION, & MAINTENANCE MANUAL

Rosedale Engineering Standards are the property of Rosedale Products, Inc.  A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale
Products, Inc.) to any individual or firm beyond the intended recipient firm or individual.  Firms of individuals acting contrary to the above may be subject to suit, ineligibility for continued or
future employment, or removal from Rosedale's "Approved Manufacturers and Specialty Contractors List".

INSTALLATION, OPERATION AND

MAINTENANCE MANUAL

ROSEDALE PRODUCTS, INC.

DUPLEX MODEL 6 

150 PSIG RATED FILTER UNIT

Table of Contents

I.

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

II.

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

III.

Spare Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

IV.

Spare  Parts  Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Summary of Contents for DUPLEX 6

Page 1: ...distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Manufacturers and Specialty Contractors List INSTALLATION OPERATION AND MAINTENANCE MANUAL ROSEDALE P...

Page 2: ...e inlet tee and one on the outlet tee ofthe Model 6 Duplex Filter unit Additionally there is one 1 4 NPT port in each cover ofthe Model 6 Duplex Filter unit These ports can remain plugged or used for pressure gauges or special fittings as your application requires Some installations require electrical grounding ofall equipment be sure to provide adequate grounding where necessary After completing ...

Page 3: ...d more than 15 PSI Differential Pressure through the filter be obtained Operating the filter unit with a high differential may cause filter bags to rupture and or cause damage to filter systemand downstream equipment To prevent excessive drop through the filter unit regular inspection ofthe filter media is required Monitoring of differential pressure through the housing can be utilized as a means ...

Page 4: ...bag is installed fully extended to the bottomofthe basket 13 Inspect cover gasket for cuts or other signs offailure and make sure it is properly seated 14 Move cover back into position and alternately tighten the three clamp assemblies evenly to ensure a leak proofseal between cover and housing body The recommended torque value for 5 8 11 closure assemblies is 150ft lbs Your Rosedale Model 6 Duple...

Page 5: ...s are the property of Rosedale Products Inc A Rosedale standard or copy thereof shall not be distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Manufact...

Page 6: ...aleproducts com Important Notice Warranty In the event any Rosedale Products Inc filtration product is found to be defective in material workmanship or not in conformance with any express warranty for a specific purpose Rosedale s only obligation and your exclusive remedy shall be to repair replace or refund the purchase price of such parts or products upon timely notification thereof and substant...