Plug the control valve into an
approved GFI power outlet us-
ing the supplied electrical cord;
operation in the service position
begins automatically.
Your MG-10 is set at the factory
default settings noted below.
You can either check or change
the settings by follow ing these
instructions.
Note:
Display will cycle every 5 to
10 seconds between the Time and
number of days until the next regen-
eration cycle. This is normal.
1. Enter
Time of Day
mode (TD on left side) by
pressing either the
Up
or
Down
arrow, and con-
tinue until display reads 12:01PM.
2. Press
Extra Cycle
button OR leave display idle
for ten seconds and
Time of Day
mode will be
exited.
3. While time reads 12:01PM
press & hold
both
the
Up
and
Down
arrows until display changes to
(DF GAL). You are now in programming mode.
1. Display should read (DF GAL)
DF = Display Format / GAL = Gallons
2. Display should read (VT FLtr)
VT = Valve Type / FLtr = Filter
3. Display should read (CT tc)
CT = Control Type / tc = Time Clock
4. Display should read (NT---1)
NT = Number of Tanks / 1 = One
5. Display should read (DO 4)
DO = Day Override (days between regeneration)
Note:
Regeneration every 4 days is the maximum recommended interval. Your source
water may require regeration cycles to be performed more often.
6. Display should read (RT 3:00)
RT = Regeneration Time / 3:00 = 3 AM
Note:
This setting represents the time of day in which the regeneration cycle will occur.
Adjust if desired.
7. Display should read (BW 15)
BW = Backwash / 15 = Fifteen Minutes
8. Display should read (BD 0)
BD = Brine Draw / 0 = Zero Minutes
9. Display should read (RR 5)
RR = Rapid Rinse / 5 = Five Minutes
Note:
When Extra Cycle button is pressed, Programming Mode will be exited.
Display will revert to normal operation. Adjust the time of day to your current local
time using the
Up
or
Down
arrows.
Programming is now complete.
For each step below, press the
Up
or
Down
arrow until the display
matches the step’s image.
Proceed to each next step by pressing the
Extra Cycle
button once.
Programming Mode - General Instructions
Entering Programming Mode
Power Failure:
In the event of power failure, the control valve will continue to keep
time for 48 hours. All programming is saved indefinitely. When power is restored,
Data Display
will flash indicating power interuption.
Press any button
and display
will stop flashing.
Manual Regeneration:
To manually regenerate filter,
press & hold
the
Extra Cycle
button for 10 seconds.
5
6
MG-10 Control Valve Master Programming