631
Figure 25-4 Loopback mode
Silent mode
In silent mode , CAN can normally receive data frames and remote frames, but can only send
recessive
bits, and can't
really send messages. If CAN needs to send overload flag, active error flag or ACK bit(these are dominant bits), such
dominant bits are internally connected back so as to be detected by the CAN core. At the same time, the CAN bus
will not be affected and still remain in the recessive bit state. Therefore, the silent mode is usually used to analyze
the activity of the CAN bus, without affecting the bus because dominant bits is not actually sent to the bus.
To enter silent mode, the CAN_BTIM.SLM bit should be set and the CAN_BTIM.LBM bit should be cleared.
CAN-CTRL
Tx
Rx
transceiver