336
/
631
Bit field
Name
Description
RTC Sub-second Register (RTC_SUBS)
Address offset: 0x28
Reset value: 0x0000 0000
Bit field
Name
Description
31:16
Reserved
Reserved, the reset value must be maintained
15:0
SS[15:0]
Sub-second value.
The value is the counter value of synchronous prescaler. This sub-second value is
calculated by the below formula:
Sub-second value = (RTC_PRE.DIVS[14:0]-SS)/( RTC_PRE.DIVS[14:0]+1)
Note: SS[15:0] can be larger than RTC_PRE.DIVS[14:0] only after the shift
operation is finished. In this case, the correct time/date is one second slower than the
time/date indicated by RTC_TSH/RTC_DATE.
RTC Shift Control Register (RTC_ SCTRL)
Address offset: 0x2C
Reset value: 0x0000 0000
Bit field
Name
Description
31
AD1S
Add one second
0: No add one second.
1: Add one second to the clock/calendar
This bit can only be written and read as zero. Writing to this bit does not have an impact
when RTC_INITSTS.SHOPF=1.
30:15
Reserved
Reserved, the reset value must be maintained
0
14
15
SUBF[14:0]
Reserved
w
16
30
31
Reserved
AD1S