CLIP Signal Name
Direction
Data Type
Description
TX/RX Delay Done
From CLIP
Boolean
Reports when an
increment/decrement
operation has
completed.
PXIe-6569 SERDES Socketed CLIP Signals
CLIP Signal Name
Direction
Data Type
Description
IO Ready
From CLIP
Boolean
Indicates successful
configuration of the
IO module with the
current clocking mode
settings.
IO Error
From CLIP
I32
Returns IO module
errors, to be reported
by the driver.
SE_Data_Output_Enab
le
To CLIP
Boolean
Provides read/write
access to all single-
ended channels.
SE_Data_Output_Enab
le values:
■
1—Use
SE_Data_Wr to
write to the SE
data line.
■
0—Use
SE_Data_Rd to
read the SE data
line value.
SE_Data_Rd
From CLIP
Boolean
SE_Data_Wr
To CLIP
Boolean
LVDS_PFI_Output_Ena
ble
To CLIP
Boolean
Provides read/write
access to all low-
voltage differential
signal (LVDS) PFI
channels.
LVDS_PFI_Rd
From CLIP
Boolean
LVDS_PFI_Wr
To CLIP
Boolean
© National Instruments
29
PXIe-6569 Getting Started Guide