background image

© 2013 National Instruments. All rights reserved. 

376090A-01

Aug13

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.

Worldwide Support and Services

The National Instruments Web site is your complete resource for technical support. At 

ni.com/support

 you have access to everything from troubleshooting and application 

development self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, 

calibration, and other services. 

Visit 

ni.com/register

 to register your National Instruments product. Product registration 

facilitates technical support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European 
Communities using the manufacturer’s declaration of conformity. This system affords the user 
protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC 
for your product by visiting 

ni.com/certification

. If your product supports calibration, 

you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world to 
help address your support needs. For telephone support in the United States, create your service 
request at 

ni.com/support

 and follow the calling instructions or dial 512 795 8248. For 

telephone support outside the United States, visit the Worldwide Offices section of 

ni.com/

niglobal

 to access the branch office Web sites, which provide up-to-date contact information, 

support phone numbers, email addresses, and current events.

Summary of Contents for NI SMD-7620

Page 1: ...t the 37 Pin Terminal Block to the 24 V Power Supply 6 Step 4 Connect the Drive Command Signals 7 Step 5 Connect the Drive Enable Signal 7 Step 6 Optional Connect the Drive Fault Signal 7 Step 7 Optio...

Page 2: ...781093 01 Separate 24 V power supply for the NI 9512 such as the NI PS 15 NI SMD 7620 7621 stepper drive NI or third party stepper motor Note NI offers stepper motors matched to the NI SMD 7620 7621 R...

Page 3: ...VIEW NI SoftMotion Module Help Use this help file to learn about using the NI SoftMotion Module in LabVIEW including information about function blocks and using the NI SoftMotion Module with the LabVI...

Page 4: ...DF by selecting Start All Programs National Instruments LabVIEW LabVIEW Manuals LV_Getting_Started pdf Hardware Installation and Configuration This section covers the hardware setup for the CompactRIO...

Page 5: ...hten the two captive screws on the front of the controller 2 Connect the controller to a power supply and an Ethernet network on the same subnet as the development computer Refer to the controller ope...

Page 6: ...the two Vsup inputs on the 37 pin terminal block The 37 pin terminal block provides a Vsup input for the NI 9512 on pin 14 and pin 22 2 Connect the V terminal from the 24 V power supply to one of the...

Page 7: ...d and I O Connector Step 5 Connect the Drive Enable Signal Complete the following steps to connect the Drive Enable signal which controls the enable function of the drive 1 Connect the X3 EN terminal...

Page 8: ...the line neutral and protective earth connectors as shown in Figure 5 2 Optional Install a fuse on the AC input line as shown The SMD 7620 contains an internal 8 A fast acting fuse The SMD 7621 conta...

Page 9: ...20 7621 Power and Motor Connector Step 9 Connect the SMD 7620 7621 to the Motor Caution Do not connect or disconnect the motor when the power is on NI offers NEMA 23 and NEMA 34 stepper motors matched...

Page 10: ...Figure 7 Figure 7 Eight Lead Motor Series Connection Note For information about connecting third party motors refer to the NI SMD 7620 7621 User Manual Figure 8 shows the NI SMD 7620 7621 motor connec...

Page 11: ...ne of the preset IP addresses or to the F position to configure the drive to use DHCP Note This document assumes you have configured the drive for DHCP For information about other settings refer to th...

Page 12: ...or additional tips Software Installation and Configuration This section covers installing and configuring software for the NI 9512 C Series module Note These instructions assume you have installed all...

Page 13: ...name and IP address 5 Click Format to start formatting the disk 6 When MAX finishes formatting the disk set the Safe Mode switch to the Off position and click OK 7 Select the System Settings tab on th...

Page 14: ...to display the Create Project dialog box You can also click the Create Project button on the Getting Started window The Create Project dialog box includes a list of templates and sample projects you...

Page 15: ...ick the controller item in the Project Explorer window and select New NI SoftMotion Axis from the shortcut menu to open the Axis Manager dialog box shown in Figure 11 11 Click Add New Axis to create a...

Page 16: ...dialog box includes configuration options for stepper drive command signals feedback devices motion and digital I O trajectory and axis setup Figure 13 shows the parts of the Axis Configuration dialo...

Page 17: ...do not have an encoder connected c Confirm that the Axis Enabled and Enable Drive on Transition to Active Mode checkboxes contain checkmarks These selections configure the axes to automatically activa...

Page 18: ...or button and make the following changes to enable NI SoftMotion to disable the drive and turn off the Drive Enable signal when the specified position error limit is exceeded Note The Monitor button i...

Page 19: ...t click the controller item in the Project Explorer window and select Deploy All to deploy the axis information 11 Select File Save Project to save the project Step 5 Configure the Drive Using the NI...

Page 20: ...onfiguration dialog box 1 Right click the axis in the Project Explorer window and select Interactive Test Panel from the shortcut menu Opening this dialog box sends the axis settings to the hardware a...

Page 21: ...ers Visit ni com services for NI Factory Installation Services repairs extended warranty calibration and other services Visit ni com register to register your National Instruments product Product regi...

Reviews: