5.

Click 

Next

 to install the selected software on the controller. Click 

Help

 if you need 

information about installing recommended software sets.

6.

When the software installation completes, click 

Finish

 to reboot the controller.

7.

Close MAX.

Step 2: Create a Project in Scan Interface Mode

Scan Interface mode enables you to use C Series modules directly from LabVIEW Real-Time. 
Modules that you use in Scan Interface mode appear directly under the chassis item in the 

Project Explorer

 window. Unlike most C Series modules, NI 951x modules are not directly 

configurable from the 

Project Explorer

 window and no I/O variables are directly available 

under the module. 

Tip

Refer to the 

Select Programming Mode Dialog Box

 topic of the 

CompactRIO 

Reference and Procedures (Scan Interface)

 help file for more information about Scan 

Interface mode. 

Use a LabVIEW project to manage VIs, targets, and I/O modules on the development computer. 
Complete the following steps to create a LabVIEW project. 
1.

Launch LabVIEW.

2.

Select 

File»Create Project

 or 

Project»Create Project

 to display the 

Create Project

 

dialog box. You can also click the 

Create Project

 button on the Getting Started window. 

The 

Create Project

 dialog box includes a list of templates and sample projects you can use 

to ensure that the project you create uses reliable designs and programming practices.

3.

Select 

Blank Project

 from the list of templates.

4.

Click 

Finish

.

5.

Select 

Help

 and make sure that 

Show Context Help

 is checked. You can refer to the 

context help throughout the tutorial for information about items on the block diagram.

Step 3: Add Resources to the Project

1.

Right-click the top-level project item in the 

Project Explorer

 window and select 

New»

Targets and Devices

 from the shortcut menu to display the 

Add Targets and Devices

 

dialog box.

2.

Make sure that the 

Existing target or device

 radio button is selected.

3.

Expand 

Real-Time CompactRIO

.

4.

Select the CompactRIO controller to add to the project and click 

OK

.

5.

If you have LabVIEW FPGA installed, the 

Select Programming Mode

 dialog box 

appears. Select 

Scan Interface

 to put the system into Scan Interface mode.

Tip

Use the 

CompactRIO Chassis Properties

 dialog box to change the 

programming mode in an existing project. Right-click the CompactRIO chassis in the 

Project Explorer

 window and select 

Properties

 from the shortcut menu to display 

this dialog box.

Summary of Contents for NI SMD-7620

Page 1: ...t the 37 Pin Terminal Block to the 24 V Power Supply 6 Step 4 Connect the Drive Command Signals 7 Step 5 Connect the Drive Enable Signal 7 Step 6 Optional Connect the Drive Fault Signal 7 Step 7 Optio...

Page 2: ...781093 01 Separate 24 V power supply for the NI 9512 such as the NI PS 15 NI SMD 7620 7621 stepper drive NI or third party stepper motor Note NI offers stepper motors matched to the NI SMD 7620 7621 R...

Page 3: ...VIEW NI SoftMotion Module Help Use this help file to learn about using the NI SoftMotion Module in LabVIEW including information about function blocks and using the NI SoftMotion Module with the LabVI...

Page 4: ...DF by selecting Start All Programs National Instruments LabVIEW LabVIEW Manuals LV_Getting_Started pdf Hardware Installation and Configuration This section covers the hardware setup for the CompactRIO...

Page 5: ...hten the two captive screws on the front of the controller 2 Connect the controller to a power supply and an Ethernet network on the same subnet as the development computer Refer to the controller ope...

Page 6: ...the two Vsup inputs on the 37 pin terminal block The 37 pin terminal block provides a Vsup input for the NI 9512 on pin 14 and pin 22 2 Connect the V terminal from the 24 V power supply to one of the...

Page 7: ...d and I O Connector Step 5 Connect the Drive Enable Signal Complete the following steps to connect the Drive Enable signal which controls the enable function of the drive 1 Connect the X3 EN terminal...

Page 8: ...the line neutral and protective earth connectors as shown in Figure 5 2 Optional Install a fuse on the AC input line as shown The SMD 7620 contains an internal 8 A fast acting fuse The SMD 7621 conta...

Page 9: ...20 7621 Power and Motor Connector Step 9 Connect the SMD 7620 7621 to the Motor Caution Do not connect or disconnect the motor when the power is on NI offers NEMA 23 and NEMA 34 stepper motors matched...

Page 10: ...Figure 7 Figure 7 Eight Lead Motor Series Connection Note For information about connecting third party motors refer to the NI SMD 7620 7621 User Manual Figure 8 shows the NI SMD 7620 7621 motor connec...

Page 11: ...ne of the preset IP addresses or to the F position to configure the drive to use DHCP Note This document assumes you have configured the drive for DHCP For information about other settings refer to th...

Page 12: ...or additional tips Software Installation and Configuration This section covers installing and configuring software for the NI 9512 C Series module Note These instructions assume you have installed all...

Page 13: ...name and IP address 5 Click Format to start formatting the disk 6 When MAX finishes formatting the disk set the Safe Mode switch to the Off position and click OK 7 Select the System Settings tab on th...

Page 14: ...to display the Create Project dialog box You can also click the Create Project button on the Getting Started window The Create Project dialog box includes a list of templates and sample projects you...

Page 15: ...ick the controller item in the Project Explorer window and select New NI SoftMotion Axis from the shortcut menu to open the Axis Manager dialog box shown in Figure 11 11 Click Add New Axis to create a...

Page 16: ...dialog box includes configuration options for stepper drive command signals feedback devices motion and digital I O trajectory and axis setup Figure 13 shows the parts of the Axis Configuration dialo...

Page 17: ...do not have an encoder connected c Confirm that the Axis Enabled and Enable Drive on Transition to Active Mode checkboxes contain checkmarks These selections configure the axes to automatically activa...

Page 18: ...or button and make the following changes to enable NI SoftMotion to disable the drive and turn off the Drive Enable signal when the specified position error limit is exceeded Note The Monitor button i...

Page 19: ...t click the controller item in the Project Explorer window and select Deploy All to deploy the axis information 11 Select File Save Project to save the project Step 5 Configure the Drive Using the NI...

Page 20: ...onfiguration dialog box 1 Right click the axis in the Project Explorer window and select Interactive Test Panel from the shortcut menu Opening this dialog box sends the axis settings to the hardware a...

Page 21: ...ers Visit ni com services for NI Factory Installation Services repairs extended warranty calibration and other services Visit ni com register to register your National Instruments product Product regi...

Reviews: