© 2008–2014 National Instruments. All rights reserved.
372498J-01
Jun14
Refer to the
NI Trademarks and Logo Guidelines
at
ni.com/trademarks
for more information on National Instruments trademarks. Other
product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National
Instruments products/technology, refer to the appropriate location:
Help»Patents
in your software, the
patents.txt
file on your media, or the
National Instruments Patents Notice
at
ni.com/patents
. You can find information about end-user license agreements (EULAs) and third-party
legal notices in the readme file for your NI product. Refer to the
Export Compliance Information
at
ni.com/legal/export-compliance
for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES
NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.
where
Raw
represents raw data returned by the NI 9381
V
corrected
represents the corrected voltage value
NI 93
8
1 Digital Channel Direction Control
Note
Both the input and output bytes are transmitted in the PDO regardless of the
direction control. You only connect relevant bits to the I/O pins.
NI 9401
The vendor configuration extensions for the NI 9401 are listed in Table 103.
NI 9401 Direction Control
Table 102.
NI 93
8
1 Digital Channel Direction Control
Bits
Field
3
0: data bit as input
1: data bit as output
2
1
0
Table 103.
NI 9401 Vendor Configuration Extensions
Index
Sub
Type
R/W
Description
0x2001
0
U32
R/W
Nibble direction control, default = 0
Table 104.
NI 9401 Scan List Format
Bits
Field
1
0: data bits <3..0> as input
1: data bits <7..4> as output
0
V
corrected
Raw
LSB
weight
10
×
7
–
(
)
×
Offset
10
×
5
–
+
=