Z
OUT
50 Ω ± 20%
....................................................................
I
OUT
(DC)
±2 mA
............................................................................
Pull-down resistor
150 kΩ
............................................................................
Recommended operating voltage
-0.3 V to 3.6 V
............................................................................
Overvoltage protection
±10 V
............................................................................
Maximum toggle frequency
6.6 MHz
............................................................................
+5 V maximum power
10 mA
............................................................................
+5 V voltage tolerance
4.2 V to 5 V
Compliance and Certifications
Safety
This product is designed to meet the requirements of the following electrical equipment safety
standards for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note
For UL and other safety certifications, refer to the product label or the
Online
Product Certification
section.
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment
for measurement, control, and laboratory use:
•
EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
•
EN 55011 (CISPR 11): Group 1, Class A emissions
•
AS/NZS CISPR 11: Group 1, Class A emissions
•
FCC 47 CFR Part 15B: Class A emissions
•
ICES-001: Class A emissions
Note
In the United States (per FCC 47 CFR), Class A equipment is intended for
use in commercial, light-industrial, and heavy-industrial locations. In Europe,
Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended
for use only in heavy-industrial locations.
Note
Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical
equipment that does not intentionally generate radio frequency energy for the
treatment of material or inspection/analysis purposes.
Note
For EMC declarations, certifications, and additional information, refer to the
Online Product Certification
section.
36 | NI 5791R User Manual and Specifications | ni.com